Power Electronics

Forward Converter

The forward converter is the isolated version of the buck — unlike the flyback, energy is not stored in the transformer: it is transferred directly to the secondary while the switch conducts (hence the name). The secondary carries a classic buck output stage: series diode D1, freewheeling diode D2 and an LC filter. Output: Vo = D·Vin/n. Because the transformer is a true ratio converter rather than an energy store, the same core moves far more power than a flyback — the classic choice for the 100–500 W band.

There is a catch: every on-time pumps magnetizing current Im into the transformer. If that current has nowhere to go, it accumulates cycle after cycle and the core saturates (= short circuit, smoke). The core must be reset every cycle. The classic fix is a third reset winding; the more elegant one is the two-switch forward: two MOSFETs (high + low) on the primary ends plus two crossed reset diodes. When both switches open, Im flows back into the source through the diodes — the primary sees exactly −Vin and the energy is recycled.

Since reset happens at −Vin, demagnetizing takes as long as magnetizing: duty can never exceed 50% (volt-second balance). As a bonus, each MOSFET in the two-switch version sees at most Vin (instead of the flyback's Vin + n·Vo) — which is why professional off-line designs love it. In our ready-made circuit, watch the reset clamp live on CH2 (the P+ node): +48 V while conducting, ~−0.9 V during reset.

Formulas

Vo = D·Vin / n (D < 0.5)
L ≥ Vo·(1−D) / (ΔIL·fs)
C ≥ Vo·(1−D) / (8·L·ΔVo·fs²)
Vds,max ≈ Vin (two-switch)

⚡ Open this lesson in the simulator — free

Test Yourself

Why can the duty cycle of a forward converter never exceed 50%?
Answer: Because the core is reset at −Vin, so demagnetizing needs as much time as magnetizing — Reset voltage −Vin equals the magnetizing voltage: volt-second balance demands reset time ≥ on time → D ≤ 0.5.
What is the fundamental difference between a flyback and a forward converter?
Answer: The flyback stores energy in the transformer; the forward transfers it directly during the on-time — Flyback = store-then-release (coupled inductor); forward = instantaneous transfer through a true transformer plus an output LC filter.